Fire door compliance checker.

Find out which fire door inspection duties apply to your building, how often doors need checking, and roughly how many inspections that adds up to each year.

Step 1What is the building used for?
Step 2How tall is the building?

Measured from ground level to the floor of the top storey.

Step 3Roughly how many fire doors?

Stairs, corridors, plant and bin stores

One per apartment

Statutory duty

Quarterly communal checks, annual flat door checks

220door inspections a year

    Your year at a glance

    1. J
    2. F
    3. M
    4. A
    5. M
    6. J
    7. J
    8. A
    9. S
    10. O
    11. N
    12. D

    Communal door checks Flat entrance door programme

    Where this comes from

      Ask for a Q-Mark maintenance quote

      General guidance for England only — not legal advice. Your fire risk assessment decides what's right for your building.

      §02The legislation

      What the rules actually say.

      A plain-English summary of the legislation and guidance the checker draws on.

      1. Fire Safety (England) Regulations 2022 — regulation 10

        In force since 23 January 2023. In residential buildings over 11 m, the responsible person must check communal fire doors (including self-closers) at least every three months, and use best endeavours to check flat entrance doors at least every 12 months. In any building with two or more sets of domestic premises, residents must be given information about fire doors.

      2. Regulatory Reform (Fire Safety) Order 2005 — article 17

        Applies to most non-domestic premises and the common parts of residential buildings. Fire safety measures, fire doors included, must be maintained in efficient working order and good repair. No fixed interval is set, so the fire risk assessment drives the frequency.

      3. Fire Safety Act 2021

        Makes clear that, in multi-occupied residential buildings, the fire risk assessment must cover the building's structure, external walls and flat entrance doors.

      4. BS 9999 and industry guidance

        Widely referenced guidance recommends checking fire doors at least every six months, and more often where doors see heavy traffic or are vulnerable to damage.

      5. Building Safety Act 2022

        Residential buildings of 18 m or more, or seven or more storeys, with at least two residential units are higher-risk buildings, with further duties for the accountable person.

      §03Next step

      Turn duties into a schedule you don't think about.

      Our BM TRADA Q-Mark fire door maintenance programmes set the inspection cycle, carry out repairs and keep the records, so you can show you're meeting your duties.

      Explore fire door maintenance
      • Inspections on schedule

        Quarterly, six-monthly or annual cycles matched to your building.

      • Faults fixed

        Common defects corrected by certified operatives, often on the same visit.

      • Records ready

        Door-by-door evidence for your fire risk assessor, insurer or auditor.

      Want us to take inspections off your plate?

      Whether it's a fire door survey, a maintenance programme or a full refurbishment, talk to us. We'll tell you straight what's needed and what it'll take.