Fire doors installed to the standard they were tested to.

A fire door is only as good as its installation. As BM TRADA Q-Mark certified installers, we fit doorsets exactly as their test evidence requires — then label and certify every one, so you can prove it.

Scheme
BM TRADA Q-Mark FDI
Certification body
UKAS 0012
Doorsets
FD30 · FD60
Sectors
Residential · Commercial · Hospitality
Fire doorset with access control keypad, pull handle and blue mandatory fire door sign

§01Overview

BM TRADA Q-Mark fire door installation

BM TRADA certified door condition surveys and installations are a critical part of keeping a building safe and compliant with fire regulations. Q-Mark certification is recognised across the industry as a mark of quality and reliability — it means our work is independently audited, not just self-declared.

Whether you're replacing failed doors across a residential block or specifying new doorsets for a fit-out, we survey, supply, install and hand over with the paperwork your fire risk assessor will ask for.

§02Scope

What's included

  1. 01.1

    Door condition surveys

    Door-by-door assessment of leaf, frame, gaps, seals, glazing, hardware and signage, with clear repair-or-replace recommendations.

  2. 01.2

    New doorset installation

    FD30 and FD60 doorsets fitted to the manufacturer's test evidence — frame fixings, packers, fire-stopping and ironmongery included.

  3. 01.3

    Replacement programmes

    Phased replacement across occupied buildings, planned around residents, tenants and trading hours.

  4. 01.4

    Flat entrance doorsets

    Front doors that meet fire, security and acoustic requirements, installed with minimal disruption to residents.

  5. 01.5

    Ironmongery & closers

    Self-closing devices, hinges, locks, hold-open devices and signage specified to suit the door's certification.

  6. 01.6

    Certification & handover

    Each Q-Mark installation is labelled and backed by a certificate, giving you a traceable record for every door.

§03Checklist

What we check, every time.

The essentials, recorded on every visit.

Inspection sheetSmiths Contractors Ltd
  1. 01Leaf and frame compatible with test evidence
  2. 02Gaps checked against the door's certification
  3. 03Intumescent and smoke seals continuous
  4. 04Self-closer fully closes and latches from any angle
  5. 05Hinges, fixings and ironmongery correctly rated
  6. 06Frame-to-wall gap fire-stopped
  7. 07Signage fitted where required
  8. 08Q-Mark label applied and certificate issued
BM TRADA Q-Mark fire door installer label fixed to the edge of a door leaf
Every certified install is labelled
Q-Mark
BM TRADA certifiedFire door installerCert. no. 3577 · UKAS 0012

§04The Q-Mark difference

Tested product + certified install = a door that performs.

Fire doors are tested as complete assemblies. Change the gaps, the hinges, the seals or the fixings and that test evidence no longer applies. Our certified installers fit to the evidence, every time.

  • Survey first

    We record each door's condition before recommending repair or replacement.

  • Fit to test evidence

    Frames, fixings, ironmongery and fire-stopping installed as the manufacturer's certification requires.

  • Label and certify

    Each installation is labelled and certified, giving you a permanent, traceable record.

Smiths Contractors did a fantastic job refurbishing our entrance doorsets to our 3 tower, 600 apartment residential complex. The work was carried out professionally, on schedule, and the estate looks so much better for it. Highly recommended.

Wes RogersBuilding and Facilities Manager, CentrickFire door installation

§05How we work

Survey. Report. Deliver. Certify.

The same disciplined sequence on every job, from a single doorset to a full estate.

  1. 01

    Survey

    We inspect every door, or walk the project with you, and record exactly what we find.

  2. 02

    Report & price

    You get clear findings, options and a fixed scope before any work begins.

  3. 03

    Deliver

    Certified operatives and project managers carry out the work around your building's routine.

  4. 04

    Certify & record

    Doors are labelled and certified, and you receive the records that prove compliance.

§06FAQ

Common questions

What does Q-Mark certification actually mean?

It means our installation work is audited by BM TRADA, a UKAS-accredited certification body. Certified installs are labelled and certified, giving a building owner independent evidence that a door was fitted correctly — not just a contractor's word.

Can you survey our existing doors before we commit to replacement?

Yes. A door condition survey tells you which doors can be repaired, which need replacing and why. Plenty of doors can be brought back into compliance without a full replacement.

Do you work in occupied buildings?

Most of our work is in buildings that stay open — residential blocks, offices and trading venues. We plan sequencing and access so residents and staff are disrupted as little as possible.

Thinking about your next project?

Whether it's a fire door survey, a maintenance programme or a full refurbishment, talk to us. We'll tell you straight what's needed and what it'll take.